Key Takeaways
- Space vector PWM is time averaging across eight inverter switch states, and the hexagon is the record of that averaging.
- Sector selection and dwell times become checkable facts once students compare hand calculations with simulated gate signals.
- Pairing every diagram with its waveform gives students a working model of the inverter that outlasts a memorized figure.
Space vector modulation makes sense to students once every hexagon diagram sits beside the inverter waveform it produces.
Most courses introduce space vector PWM with a hexagon, six sectors and a rotating arrow, then move straight to equations. The drawing is clear to whoever drew it and opaque to everyone else in the room. That gap matters because the technique runs the inverters behind most modern motor drives, and electric motor systems account for more than 40% of global electricity consumption.
The fix is simple, and it’s a teaching choice. Treat the hexagon as a map of switch states, and treat the waveform as the evidence that the map is correct. When students step through sector selection and dwell times inside an inverter model, each geometric step produces a voltage they can measure.
“The technique is time averaging, and the hexagon is bookkeeping for it.”
What space vector PWM does inside a three-phase inverter
Space vector PWM is a switching method that treats the three phase voltages of an inverter as one rotating vector. The controller approximates that reference vector during each switching period with a timed mix of the inverter’s eight possible switch states. The average of those states over the period equals the voltage you asked for.
Picture a two-level inverter on a 400 V DC bus feeding an induction motor. Each of the three legs connects its phase to either the positive or the negative rail, so the inverter can only produce a handful of discrete voltages. The motor needs a smooth sinusoidal signal, so the modulator spends a calculated fraction of every period in each of two neighbouring states, plus some time in a zero state.
The technique is time averaging, and the hexagon is bookkeeping for it. Open with the three legs and the averaging, and the shape becomes something your class could have drawn without help.
How the hexagon maps eight switch states to output voltage
The hexagon is a plot of the eight switch states on a two-axis plane. Six active states sit at the corners, each with a magnitude of two-thirds of the DC bus voltage and spaced 60 degrees apart. The two zero states, where all three legs connect to the same rail, sit at the origin.
Take state 100, where leg A is high and legs B and C are low. On a 400 V bus, phase A sits at 266.7 V relative to the load neutral, and phases B and C sit at -133.3 V. Plot those three values on the alpha-beta plane and you get a vector of 266.7 V pointing along the phase A axis. State 110 rotates it by 60 degrees.
Have students build the corners this way, one state at a time, with the simulated phase voltages open beside the diagram. Six runs later they’ve drawn the hexagon from measurements. The label on each corner now means something physical.
How sector selection identifies the two active vectors to use
Sector selection finds which of the six 60 degree wedges contains the reference vector at a given instant. The two active vectors that border that wedge are the only ones used during the switching period. The angle of the reference decides the sector, and the sector decides which legs switch.
A reference at 30 degrees falls in sector 1, bounded by states 100 and 110. Students often compute the sector correctly and still can’t say what it means for the hardware, so ask them to read the gate signals. Sector 1 means leg C stays low for nearly the whole period while legs A and B do the work. Most classroom errors start here too. An angle wrapped incorrectly at 360 degrees, or a sector index that begins at 0 in code and 1 on the slide, produces a waveform with a visible notch every sixth of a cycle. That notch points at the exact sector where the logic broke.
“When the simulated gate signals match the hand calculation, the formula stops being something to memorize.”
How dwell times are calculated from the reference vector
Dwell times are the durations spent in each active vector and in the zero vectors during one switching period. You calculate them so the time-weighted average of the applied vectors equals the reference. For an angle θ inside the sector, T1 equals Ts times m times sin(60° − θ), T2 equals Ts times m times sin(θ), and the zero time is the remainder.
Here, m is the modulation index, which is the square root of 3 times the reference amplitude divided by the DC bus voltage. With a 400 V bus, a 200 V reference at 30 degrees and a 100 microsecond period, m is 0.866. Both active vectors get 43.3 microseconds, and the zero vectors share the remaining 13.4 microseconds.
Then check it against the simulation. With the zero time split evenly across a symmetric sequence, students should find leg A high for about 93% of the period, leg B for 50% and leg C for 7%. When the simulated gate signals match the hand calculation, the formula stops being something to memorize. A mismatch is just as useful, because it gives the student a specific number to chase.
The main difference between space vector and sinusoidal PWM
The main difference between space vector PWM and sinusoidal PWM is how the switching pattern is produced. Sinusoidal PWM compares three separate sine references with a triangular carrier, one phase at a time. Space vector PWM treats the three phases as a single vector and computes the timing for all three legs at once.
That single-vector view is where the efficiency claim comes from. It places the zero states so the line-to-line voltage can go higher before the inverter saturates. Within the linear range, space vector PWM raises fundamental output voltage by 15.5% over sinusoidal PWM, a result reported in a Boise State University simulation study. On the 400 V bus from the earlier case, the peak phase voltage limit moves from 200 V to about 231 V.
| Point of comparison | Sinusoidal PWM | Space vector PWM |
| How the switching pattern is produced | Each phase is compared with a carrier separately | One vector sets the timing for all three legs |
| Peak phase voltage available on a 400 V bus | The linear range ends at 200 V | The linear range extends to about 231 V |
| What students calculate by hand | One amplitude ratio per phase | A sector and three dwell times per period |
| Typical harmonic result | Harmonic distortion is higher overall | Lower harmonic distortion is reported |
| Where a class usually gets stuck | The voltage limit stays hidden | The geometry feels abstract without a waveform |
More voltage from the same bus means a motor reaches its rated operating point with DC hardware that’s no larger than before. Your students can confirm that with both modulators on the same inverter model.
How to simulate space vector modulation step by step in class

You simulate space vector modulation with a reference generator, a sector and dwell time calculation, a switching sequence block and a two-level inverter feeding a three-phase load. Build it in stages and plot something after each one, so the geometry stays attached to the voltage.
SPS SOFTWARE works inside MATLAB/Simulink with open, editable component models, so a class can step through sector selection and dwell times inside an inverter model and inspect what each block computes. A lab sequence that works well follows 5 stages.
- Plot the three reference voltages as one rotating vector on the alpha-beta plane.
- Add sector detection and display the sector number against the reference angle.
- Calculate the dwell times and confirm they sum to the switching period.
- Generate the gate signals and compare each duty cycle with a hand calculation.
- Filter the line-to-line voltage and compare it with the original reference.
Keep the switching frequency low at first, around 1 kHz, so individual pulses stay visible on the scope. Each stage should end with a hexagon sketch and a waveform side by side in the lab report.
What students keep when the hexagon sits beside the waveform
Students who pair each diagram with its waveform keep a working model of the inverter, and that lasts longer than a memorized figure. They can explain why a sector matters, predict a duty cycle before running anything and recognize a wrong result on sight. That’s the outcome worth designing a lab around.
Space vector modulation has a reputation as the hard week of a power electronics course, and most of that reputation comes from the order things are taught in. Geometry first and results later asks students to trust a drawing for two lectures. Put results beside geometry and every claim on the board has a trace next to it that either agrees or doesn’t. That habit of checking a diagram against a measurement carries well past this one topic. Instructors who want students reproducing the sequence themselves can ask about the SPS SOFTWARE educational offer. Give your class the diagram and the trace on one page, and the hard week becomes one of the clearer ones.